PO Box 1232 Freeport, IL 61032

State-Mandated Annual Reporting of the Biennial Hazardous Waste Report

RCRA Hazardous Waste Regulations

State-Mandated Annual Reporting of the Biennial Hazardous Waste Report

Federal regulations of the Environmental Protection Agency (USEPA) at 40 CFR 262.41 require a generator who is a large quantity generator (LQG) of hazardous waste for at least one month in an odd-numbered year to submit the Biennial Report (aka: Biennial Hazardous Waste Report).  The generator must  complete the report using EPA Form 8700-13 A/B and submit it to the EPA Regional Administrator by March 1 of the following even-numbered year.

Not sure of your hazardous waste generator status?

 Take this short survey

A state with an authorized hazardous waste program may choose to make its regulations more strict than those of the USEPA.  One may that some states do this is to require an annual report from hazardous waste generators in their state.  Below is a table identifying the states by EPA Region that request an annual report instead of biennial from hazardous waste generators within their jurisdiction.

Proper Shipping Name
(2)
Hazard Class
(3)
ID #
(4)
PG
(5)
Packaging Exceptions
(8A)
Allyl isothiocyanate, stabilized6.1UN1545II153
Aluminum smelting by-products or Aluminum remelting by-products4.3UN3170II151
III151
Amine, liquid, corrosive,
flammable, n.o.s.
or
Polyamines, liquid, corrosive,
flammable, n.o.s
8UN2734INone
II154
Amyl mercaptan 3UN1111II150
Antimony pentachloride,
liquid
8UN1730II154
Antimony pentafluoride8UN1732II154
Batteries, dry, containing
potassium hydroxide
solid
, electric storage
8UN3028154
Borneol4.1UN1312III151
5-tert-Butyl-2,4,6-trinitro-mxylene or Musk xylene4.1UN2956III159
1,4-Butynediol6.1UN2716III153
Calcium resinate4.1UN1313III151
Calcium resinate, fused4.1UN1314III151
Camphor, synthetic4.1UN2717III151
Celluloid, in block, rods, rolls,
sheets, tubes, etc., except
scrap
4.1UN2000III151
Cerium, slabs, ingots, or rods4.1UN1333II151
Chloric acid aqueous
solution,
with not more than
10 percent chloric acid
5.1UN2626II152
1-Chloropropane3UN1278II150
Chromium trioxide,
anhydrous
5.1UN1463II152
Corrosive liquids, flammable,
n.o.s.
8UN2920INone
II154
Corrosive liquids, oxidizing,
n.o.s.
8UN3093INone
II154
Corrosive solids, flammable,
n.o.s.
8UN2921INone
II154
Corrosive solids, oxidizing,
n.o.s.
8UN3084INone
II154
Corrosive solids, waterreactive, n.o.s.8UN3096INone
II154
Corrosive liquids, oxidizing,
n.o.s.
8UN3093INone
II154
Corrosive solids, oxidizing,
n.o.s.
8UN3084INone
II154
Corrosive solids, self-heating,
n.o.s.
8UN3095INone
II154
Corrosive solids, waterreactive, n.o.s.8UN3096INone
II154
Cyanuric chloride 8UN2670IINone
Cyclohexylamine8UN2357II154
Decaborane4.1UN1868II151
Detonator assemblies, nonelectric, for blasting1.4BUN036163(f),
63(g)
Detonators, electric, for
blasting
1.4BUN025563(f)
63(g)
Detonators for ammunition1.4BUN0365None
Detonators, non-electric, for
blasting
1.4BUN026763(f),
63(g)
Diethyl sulfide3UN2375II150
2-Diethylaminoethanol8UN2686II154
N,N-Diethylethylenediamine8UN2685II154
Diethylthiophosphoryl
chloride

8UN2751II154
Difluorophosphoric acid,
anhydrous
8UN1768II154
Di-n-butylamine8UN2248II154
Ethyl bromoacetate6.1UN1603II153
Fibers or Fabrics impregnated
with weakly nitrated
nitrocellulose, n.o.s.
4.1UN1353III151
Films, nitrocellulose
base,
gelatine coated (except
scrap)
4.1UN1324III151
Firelighters, solid with
flammable liquid
4.1UN2623III151
Flammable solid, oxidizing,
n.o.s
4.1UN3097II151
III151
Flammable solids, corrosive,
organic, n.o.s.

4.1UN2925II151
III151
Fluorophosphoric acid
anhydrous
8UN1776II154
Fluorosilicic acid8UN1778II154
Gallium8UN2803III154
Hafnium powder, wetted with
not less than 25 percent water
(a visible excess of water must
be present) (a) mechanically
produced, particle size less
than 53 microns; (b)
chemically produced, particle
size less than 840 microns
4.1UN1326II151
Hexadienes3UN2458II150
Hexafluorophosphoric acid8UN1782II154
Hexamethylenediamine
solution
8UN1783II154
III154
Hydrazine aqueous
solution
, with more than 37%
hydrazine, by mass
8UN2030INone
II154
Hydrogen peroxide and
peroxyacetic acid mixtures,
stabilized
with acids, water,
and not more than 5 percent
peroxyacetic acid
5.1UN3149II152
Hydrogen, peroxide, aqueous
solutions with more than 40
percent but not more than 60
percent hydrogen peroxide
(stabilized as necessary)
5.1UN2014II152
Hydrogen peroxide, aqueous
solutions with not less than 20
percent but not more than 40
percent hydrogen peroxide
(stabilized as necessary)
5.1UN2014II152
Hydrogendifluoride, solid,
n.o.s.
8UN1740II154
III154
Iodine monochloride, solid8UN1792II154
Lead phosphite, dibasic4.1UN2989II151
Mercaptans, liquid,
flammable, toxic,
n.o.s.
or Mercaptan mixtures, liquid, flammable, toxic, n.o.s.
3UN1228II150
III150
2-Methyl-2-butene3UN2460II150
Methylal3UN1234II150
Nitrating acid mixtures
spent
with not more than 50
percent nitric acid
8UN1826II154
Nitrating acid mixtures with
not more than 50 percent
nitric acid
8UN1796II154
Nitric acid other than red
fuming, with at least 65
percent, but not more than 70
percent nitric acid
8UN2031II154
Nitric acid other than red
fuming, with more than 20
percent and less than 65
percent nitric acid
8UN2031II154
Nitric acid other than red
fuming with not more than 20
percent nitric acid
8UN2031II154
Octafluorobut-2-
ene
or Refrigerant gas R 1318
2.2UN2422306
Octafluorocyclobutane, or
Refrigerant gas RC 318
2.2UN1976306
Octafluoropropane or Refriger
ant gas R 218
2.2UN2424306
Organometallic substance,
liquid, water-reactive

4.3UN3398INone
II151
III151
Organometallic substance,
liquid, water-reactive,
flammable
4.3UN3399INone
II151
III151
Organometallic substance,
solid, water-reactive, selfheating
4.3UN3397INone
II151
III151
Oxidizing liquid, corrosive,
n.o.s.
5.1UN3098INone
II152
III152
Oxidizing solid, water
reactive, n.o.s.
5.1UN3121INone
II152
Perchloric acid with not more
than 50 percent acid by mass

8UN1802II154
Peroxides, inorganic, n.o.s. 55.1UN1483II152
III152
Phosphorus heptasulfide, free
from yellow or white
phosphorus
4.1UN1339II151
Phosphorus, amorphous4.1UN1338III151
Phosphorus oxybromide8UN1939II154
Phosphorus pentachloride8UN1806II154
Phosphorus sesquisulfide, free
from yellow or white
phosphorus
4.1UN1341II151
Phosphorus tribromide8UN1808II154
Phosphorus trisulfide, free
from yellow or white
phosphorus
4.1UN1343II151
Propionitrile3UN2404II150
1,2-Propylenediamine8UN2258II154
Pyridine3UN1282II150
Silicon powder, amorphous4.1UN1346III151
Sludge, acid8UN1906II154
Sodium chlorite5.1UN1496II152
Sulfur4.1UN1350III151
Sulfuric acid, spent8UN1832II154
Tetrafluoromethane or
Refrigerant gas R 14
2.2UN1982306
Tetrahydrofuran3UN2056II150
Thiophosphoryl chloride 88UN1837II154
Titanium hydride4.1UN1871II151
Titanium powder, wetted with
not less than 25 percent water
(a visible excess of water must
be present) (a) mechanically
produced, particle size less
than 53 microns; (b)
chemically produced, particle
size less than 840 microns
4.1UN1352II151
Titanium sponge granules or
Titanium sponge powders
4.1UN2878III151
Toxic liquids, water-reactive,
n.o.s
6.1UN3123INone
II153
Toxins, extracted from living
sources, liquid, n.o.s.
6.1UN3172INone
II153
III153
Toxins, extracted from living
sources, solid, n.o.s.

6.1UN3462INone
.II153
III153
Toxins, extracted from living
sources, solid, n.o.s
6.1UN3462INone
II153
III153
Triallylamine3UN2610III150
Water-reactive liquid,
corrosive, n.o.s.
4.3UN3129INone
II151
III151
Water-reactive liquid, n.o.s.4.3UN3148INone
II151
III151
Water-reactive liquid, toxic,
n.o.s.
4.3UN3130INone
II151
III151
Water-reactive, solid,
oxidizing, n.o.s.
4.3UN3133II151
III151
Zinc ammonium nitrite5.1UN1512II152
Zinc chloride, anhydrous8UN2331III154
Zirconium hydride 4.1UN1437II151
Zirconium powder,
wetted
with not less than 25
percent water (a visible excess
of water must be present) (a)
mechanically produced,
particle size less than 53
microns; (b) chemically
produced, particle size less
than 840 microns
4.1UN1358II151
Zirconium suspended in a
liquid
3UN1308INone
II150
III150

Other instances where state regulations for hazardous waste reporting are more strict than those of the USEPA:

  • Require reporting for small quantity generators (SQGs) of hazardous waste as well as LQGs.
  • Require reporting more frequently than annual, e.g. quarterly.
  • Collect a fee from hazardous waste generators.

Contact me with any questions you may have about the generation, identification, management, and disposal of hazardous waste

Daniels Training Services, Inc.

815.821.1550

Info@DanielsTraining.com

https://danielstraining.com/

Share This:

Search Website